The VCL dome camera was unquestionably the number 1 fully functional PTZ dome camera sold during the late 90’s and throughout the early part of this decade.VCL built an unenviable record for innovation and reliability. The orb 5, orb 6 and orb gold were sold extensively in the UK however world wide sales were impressive. At the height of the of VCL’s dome domination they were shipping over 1200 per month. This attracted some big players and the company was finally sold to Honeywell in 2004. Honeywell continued production of the Orb gold under the Honeywell camera brand name before finally phasing it out around 4 years ago. Honeywell continued with repairs of the VCL dome until finally ending this 3 years ago. Since this there has been limited options for installers and end-users when their VCL/Honeywell dome camera goes faulty.

Purchase a new dome inner for a cost effective solution to your VCL/Honeywell dome camera problems.

Common faults include.

1) Camera out of focus: this is caused by the lens motor inside the camera module failing.

2 No control over camera: this can be caused by several things but top of the list is a snapped/broken bayonet or the main PCB inside dome head is not communicating with the matrix.

3) Camera resting on the dome acrylic: This is defiantly caused by the bayonet snapping/breaking.

4) Intermittent picture/control: The slip rings have worn out.

5) Can’t tilt camera up or down: The tilt motor has gone faulty.

6) Can’t move the camera from side to side: The pan motor has gone faulty.

7) Picture has gone white or black: The camera module lens is faulty.

Of course there are other reasons that it may seem the camera is faulty i.e. the coax is down or there is no power to the camera, the maxcom matrix may be faulty or of course the keyboard may have issues. These problems are however rare and in the majority of cases the dome camera inner is at fault.

The most cost effective solution with all the above cameras is to replace the inner, these are hard to come by and will be old and subject to the same issues highlighted above. If access to the camera is via cherry picker then as an installer you will know what costly business it is to mess about with an old dome inner trying to get a repair that is often costly and ineffective. So, is there an alternative?

THE SOLUTION.

Well yes, we are now able to provide a dome inner that has been specifically modified to fit into a VCL/Honeywell housing. The inner is designed and manufactured by a highly reputable dome manufacturer and incorporates all the features of the VCL dome and more. The best part for all involved is that it has been designed to work with the maxcom matrix and handset meaning all controls can remain in situ. We provide a 12 month guarantee and the inner can be purchased for often less than a full repair and service on an old unit. We offer discount for bulk purchases from abroad.

If you would like to purchase the 360/24v dome inner then buy here.

VCL Orbiter gold. DIY repair.

The VCL orbiter gold PTZ cameras can be seen across all areas of the UK. One of the most popular dome cameras of their time they sold thousands of units. Now however they are no longer manufactured and maintaining them has become difficult , if not impossible. There are some fixes however that can be made by the end user and this may solve or prolong the life of your dome camera. Below we list the most common faults and how to fix them without the need to call out an engineer.

1) Camera out of focus: this is caused by the lens motor sticking. You can rectify this by powering down the camera. Go to the power supply probably situated at the bottom of the pole or in the building just behind the dome. There will be a fused spur powering this, remove the fuse, leave for a minute or two then power up again. This will enable the camera to restart and should cause the camera to refocus. This fix is never permanent but you should get a good two weeks out of it before having to repeat the power up/down process. The Sony camera blocks are no longer made so a permanent fix will need a new dome inner.

2) Camera picture flicking and losing tour.: this will be caused by the slip rings, these slip rings allow the dome to spin but still provide power to the camera and motors. The solution is quite simple, you need to reprogram the tour so that it does not pass over the worn area of the slip ring. This is done by moving the offending preset to a new position. Sometimes a marginal change will allow the dome to carry on working for many further months. Once however the slip ring is so worn this process fails to work a new inner will be required.

3)  No camera picture at all: two things to check here. Do you have power at the dome? You need to check mains is present at the fused spur and if it is check the fuse in the PSU. Often moisture inside the VCL dome housing can blow the fuse .You may be advised to see how the water has ingressed into the housing to prevent a repeat, sometimes you will find it has been hit or damaged or the acrylic has not been replaced properly at some point. The second reason could again be the slip rings, if there is no picture you will need to remove the fuse in the spur adjacent to the PSU and initiate a re boot. This should restore the image .Then you need to find the weak spot in the slip ring and carry out the process outlined in point 2 to avoid this worn part of the slip ring, you may get a few more months out of your VCL dome camera.

4) Intermittent control over the dome camera:This is the camera losing its connection with the Maxcom gold matrix. This could be a poor connection on the back of the  Maxcom matrix or a damaged cable. Remake the connections or rejoin the cable. This if it is the case then you will be provided with a permanent fix.

5)  Picture is white: The auto iris lens has been put onto manual and opened fully letting too much light into the lens. Adjust the lens manually with auto focus button on the control and the picture will return . Lock the keypad so the buttons cannot be accidentally touched again.

6)  Picture is Black: Same as above but the iris has been closed right down letting no light into the camera.

Of course there are many other faults that can manefest themselves and we are happy to advise if you wish to contact us. There are also ways of replacing the inner for a fraction of the cost of a new external dome camera. So always investigate this option before spending thousands on a new system, including having to replace the  keyboard controls and the Honeywell  Maxcom gold matrix.

CCTV Solutions

Here at Integrated CCTV we are striving to bring you the latest CCTV news from the industry . New products can be found on this site including the latest offerings from:

Avigilon

Arecont

Alhua Technology

360 vision technology

Basler

Axis IP camera

Bosch,

Brickcom

Cisco,

Custodian monitoring

Dual com,

VCL Dome camera,

Dallmeier

FLIR

HD CCTV

Milestone,

Maxxess

March networks,

motobotix,

Mayflex

Panasonic

Paxton

Redcare,

Risco

Siemans

Samsung

Sony

Vicon,

Videx,

Videcon,

veracity UK ltd

Xtralis

Plenty to look at search the site to find blogs and updates on all the CCTV products in the news.

VCL dome repair solution

VCL dome repairs.

VCL were a company who were one of the great success stories of the late nineties and early part of this century. They were a British organisation who revolutionised the CCTV market with their orbital domes.

Takeover

Their success was soon recognised and take over was inevitable. First Ademco then Honeywell also profited from the success of the dome through aggressive take-overs. Buy dome spares

Honeywell.

Honeywell however have fingers in many pies and the orb 6 and orb gold dome was eventually superseded with Honeywell’s own product lines, no surprise but a great shame. One thing however has over the last couple of years though has been neglected and that’s repairs of the domes themselves! The CCTV domes won’t last forever. They have moving parts and are of course vulnerable to wear and tear. Some large repair houses will take on refurbishments but Honeywell no longer support the product.

VCL orb gold camera

It is here that a great opportunity exists for companies willing to help out the tens of thousands of end users out there that still have VCL domes and still need them as part of their overall security package. 360 vision technology are one company that we have sourced that has cleverly taken advantage of what is going to be a very large market as the VCL domes reach the end of their life cycle.

The 360 dome inner

The 360 vision dome inner can be adapted to fit into the existing orb gold housing. This dramatically reduces the cost of an upgrade and often works out cheaper than actually trying to repair the old dome inner itself. The outer housings of the VCL dome are brilliantly robust and will go on working for years without needing any attention at all, so the smart businesses out there might find a cost effective solution with 360 vision technology.

Repair it!

Servicing a VCL dome can also be carried out by Maxey Moverley. This is a repair house that has  skilled staff to look after the inevitable rise in demand to fix what after all is a very good product, many years after its original conception.